Ultrasonic Oxygen Analyzer Handheld
Product Code : EL-RAAE-10963
Quick Answer: Ultrasonic Oxygen Analyzer Handheld is a hand-held, battery powered analyser that uses ultrasonic sensing to measure oxygen concentration and flow rate from a medical gas source, covering 21 - 96 % O2 with accuracy within ± 3 %.
Last updated: October 2026
Key Features
- Ultrasonic oxygen sensing with a permanent sensing chamber
- O2 range 21 - 96 %, accuracy within ± 3 %, resolution 0.1 %
- Flow rate measurement up to at least 10 LPM, accuracy within ± 3 %, resolution 0.1 LPM
- Response time < 30 s; warm-up time < 15 s; self-calibration in typical conditions of use
- Display shows O2 concentration, flow rate, system messages and battery status
- 2 x AA alkaline batteries; battery life > 250 hours continuous use; automatic power-off
Technical Specifications
| Specification | Value |
|---|---|
| Sensing | Ultrasonic, permanent sensing chamber |
| O2 range | 21 - 96 % |
| O2 accuracy | Within ± 3 % |
| O2 resolution | 0.1 % |
| Flow rate measurement | Up to at least 10 LPM |
| Flow rate accuracy | Within ± 3 % |
| Flow rate resolution | 0.1 LPM |
| Response time | < 30 s |
| Warm-up time | < 15 s |
| Gas supply pressure | Up to 50 psi |
| Calibration | Self-calibration in typical conditions of use |
| Power | 2 x AA alkaline replaceable single use batteries |
| Battery life | > 250 hours continuous use |
| Power-off | Automatic when not in use |
About This Product
Checking the performance of gas supply equipment is the intended application of this analyser, which measures oxygen concentration in a gas flow from a medical gas source or, with adapters, through a medical gas-flow device such as a ventilator or anaesthesia system. It can make spot checks or measure continuously, calibrates itself in typical conditions of use and switches off automatically when not in use. In Resuscitation and Anaesthesiology Equipment work it handles gas supplies at pressures up to 50 psi and runs for more than 250 hours of continuous use on 2 x AA alkaline batteries.
Frequently Asked Questions
Q1. What does the oxygen analyser measure?
Oxygen concentration across 21 - 96 % and flow rate up to at least 10 LPM, both with accuracy within ± 3 %.
Q2. What batteries does it use?
2 x AA alkaline replaceable single use batteries, with a battery life of more than 250 hours of continuous use.
Q3. How fast does it respond?
Response time is under 30 s and warm-up time under 15 s.