Quick Answer: Forced Convection Apparatus measures heat transfer from a 32 mm NB GI test pipe, 500 mm long, heated outside by a band heater while a centrifugal blower forces air through it. An orifice meter with differential water manometer measures the airflow, and a multichannel digital indicator reads the temperatures.
Last updated: October 2026
Key Features
Band heater giving constant heat flux to the test pipe
Centrifugal blower with flow control valve
Orifice meter with differential water manometer
Voltmeter and ammeter for heater input
Pipe surface temperatures at various points, plus air inlet and outlet temperatures
Technical manual supplied
Technical Specifications
Specification
Value
Test pipe
32 mm NB GI pipe, 500 mm long
Heater
Band heater, outside the pipe
Blower
Centrifugal, with flow control valve
Variac
2A capacity
Airflow measurement
Orifice meter with differential water manometer
Temperature
Multichannel digital temperature indicator
Bench area
About 1 m x 0.75 m at working height
About This Product
Constant heat flux is added to the pipe by the electrical heater, and the air forced through it carries the heat away by forced convection. Pipe surface temperatures along its length and air temperatures at inlet and outlet let students calculate local and overall heat transfer coefficients at various airflow rates and heat flux values. In the HEAT TRANSFER LAB, the apparatus needs about 1 m x 0.75 m of bench space at working height.
Frequently Asked Questions
Q1. What can be calculated with the forced convection apparatus? Local and overall heat transfer coefficients in forced convection, at various airflow rates and various heat flux values.
Q2. How is the airflow measured? With an orifice meter and a differential water manometer; the blower has a flow control valve.